Sound Absorption Testing in Reverberation Room: ISO 354 & ASTM C423

Sound Absorption Testing

Sound Absorption Testing shows how much sound energy a material takes in. Labs run it in a reverberation room, built by a specialist Reverberation Chamber Manufacturer such as Ecotone Systems. The room has hard, reflective surfaces and a diffuse sound field. Two standards guide the work: ISO 354 and ASTM C423.

What Is Sound Absorption Testing in a Reverberation Room?

The reverberation room method compares decay times. The lab first measures how long sound takes to fade in the empty room. It then repeats the test with the specimen installed. The difference gives the sound absorption coefficient for each one-third-octave band.

What Do ISO 354 and ASTM C423 Cover?

ISO 354 is the international standard for the ISO 354 sound absorption test. ASTM C423 testing is the North American equivalent. Both rely on the same principle, though their specimen, mounting and reporting rules differ.

What Is NRC Testing?

NRC testing uses the ASTM C423 results. The Noise Reduction Coefficient is the average of the absorption coefficients at 250, 500, 1000 and 2000 Hz, rounded to the nearest 0.05. Acoustic panel absorption testing therefore gives specifiers a single comparable number, backed by full band data.

How Porous Is a Reverberation Chamber?

A good acoustic reverberation chamber uses hard, reflective boundaries so sound energy stays in the room. Diffusers spread that energy evenly. The porous or fibrous material is the specimen you place inside, never the room.

What Are the Benefits for Specifiers?

Echo reduction: The chamber itself does not reduce echo. Its value is the absorption data it produces, which helps you choose materials that control echo in real spaces.

Handling: Ecotone offers modular, relocatable and custom-built options, so the room can suit your site.

Installation: Delivery covers requirement study, sizing, shell fabrication, diffuser fitting, instrumentation, controller integration and qualification testing.

Repeatable results and support for large products are further advantages.

Where Is Sound Absorption Testing Applied?

  • Architects and commercial buildings: Chamber-tested absorption data guides finish selection.
  • Manufacturing plants: Teams rate the noise of appliances and equipment.
  • Educational campuses: Research and teaching labs run acoustic experiments.

What Affects the Price?

Quotations depend on:

  • Dimensions: Room volume sets the lowest usable frequency.
  • Thickness: Wall build-up is project specific.
  • Design: Diffuser system, frequency range and site fit.
  • Quantity: A single room or multiple units.
  • Installation: Site conditions, instrumentation and qualification testing.

What Are the Specifications?

Parameter Specification
Chamber volume 70 m³ to 250+ m³
Usable frequency range 100 Hz to 10 kHz, one-third-octave bands
Standards ISO 3741, ISO 3743, ISO 354
Diffuse-field method Stepped and continuous diffusers
Construction Hard reflective surfaces; modular, relocatable or custom-built
Background noise reduction Up to 10 dB(A)

Why Choose Ecotone Systems?

Ecotone is an ISO 9001:2015 certified company with over 40 years of experience. It handles design, manufacture, installation and commissioning. Pan India projects and an in-house manufacturing facility support delivery.

Frequently Asked Questions:

1. What is the purpose of Sound Absorption Testing?

It measures how well a material absorbs sound in a diffuse field, giving coefficients and an NRC value for comparison.

2. How much does a reverberation room cost?

Price depends on dimensions, thickness, design, quantity and installation. Request a quotation for a project figure.

3. Which applications suit it best?

Building-material evaluation for architects and commercial projects, product noise work in manufacturing plants, and teaching or research labs on educational campuses.

4. Does it use recycled materials?

Ecotone’s product page does not state recycled content. Ask the sales team for written confirmation before you specify it.

5. What is the difference between ISO 354 and ASTM C423?

Both use the reverberation room method. ISO 354 reports absorption coefficients, while ASTM C423 also yields NRC. Confirm which standard your project requires.

Request a Quotation

Planning Sound Absorption Testing or a new reverberation room? Contact, email –Sales@ecotone.in or call +91 98103 19823.